 SERIES
FCA-210
Tyco Electronics Mid-Range Military/Aerospace Relays
10 AMPERES, DPDT
q HERMETICALLY SEALED q ALL WELDED CONSTRUCTION q BALANCED FORCE q PERMANENT MAGNET DRIVE q CONTACTS: SILVER CADMIUM
OXIDE WITH GOLD PLATING q COILS FOR DC, 50 TO 400Hz AND 400Hz AC q WEIGHT 1.6 OUNCES MAX. (45.4 GRAMS) The Series FCA-210 relay is a polarized single-side stable design, where the flux from a permanent magnet provides the armature holding force in the deactivated state, and its flux path is switched and combined with the coil flux in the operated state. This results in appreciably increased contact pressure in both states over that of a spring return nonpolar design. We also manufacture other versions of this relay: FCA-410: 10 AMPERE 4PDT RELAY FCA-610: 10 AMPERE 6 PDT RELAY
QPalified to MIL
Qu
ED PRO-V3536 L AP -R 8
AVAILABLE FCA-215: 15 AMPERE DPDT RELAY, HAS THE SAME SPECIFICATIONS AS THE FCA-210 EXCEPT IS RATED AT 15 AMPS. CONTACT RATING-AMPERES
Ratings Are Continuous Duty TYPE OF LOAD Resistive Inductive Motor Lamp LIFE (MIN.) CYCLES X 103 100 20 100 100 28 VDC 10 8 4 2 115VAC 400Hz 10 8 4 2 115/200VAC 30 400 Hz 60Hz * 10 8 4 2 2.5 2.5 2.0 1
* 60 Hz LOADS RATED FOR 10,000 OPERATIONS OVERLOAD CURRENT 40 AMPS DC, 60AMPS 400Hz RUPTURE CURRENT 50 AMPS DC, 80 AMPS 400Hz CONTACT MAKE BOUNCE 1 MILLISECOND AT NOMINAL VOLTAGE MAX. CONTACT DROP AT 10 AMPS: INITIAL 0.100 VOLTS. END OF LIFE 0.125 VOLTS
8
SERIES
FCA-210
Tyco Electronics Mid-Range Military/Aerospace Relays
10 AMPERES, DPDT
COIL DATA
COIL CODE 1 2 3 4 (A) 5 6 7 8 9 NOMINAL VOLTAGES 6 12 28 28 48 28 28 115 115 FREQ. Hz DC DC DC DC DC 400Hz 50/400Hz 400 Hz 50/400Hz OVER TEMPERATURE RANGE DC RES. DROPOUT OR MUST HOLD PICKUP OR AC AMPS (B) BELOW VOLTS ABOVE VOLTS VOLTAGE (C) 20 80 320 320 920 180 mA 100 mA 40 mA 30 mA 4.5 9.0 18.0 18.0 32.0 22.0 22.0 90.0 95.0 0.3 0.75 1.5 1.5 2.5 1.25 1.25 5.0 5.0 2.5 4.5 7.0 7.0 14.0 10.0 10.0 40.0 40.0
A. CODE 4 COILS HAVE BACK EMF SUPPRESSION D. MAX. OVERVOLTAGE: 6 & 12 VDC COILS 120% OF TO 42 VOLTS MAX. NOMINAL; ALL OTHERS 110% OF NOMINAL. B. DC COIL RESISTANCE 10% AT 25C; E. COILS AVAILABLE FOR OTHER VOLTAGES AND AC COIL MAX. CURRENT AT NOMINAL VOLTAGE. FOR AC 50/60HZ. C. RELAY WILL STAY IN PICKED-UP STATE DOWN TO MUST HOLD VOLTAGES SHOWN. NOTE: Only DC Coil Models are QPL Approved.
GENERAL SPECIFICATIONS
TEMPERATURE RATING: ALTITUDE: SHOCK:* VIBRATION, SINUSOIDAL:* VIBRATION, RANDOM: * DIELECTRIC STRENGTH AT SEA LEVEL: DIELECTRIC STRENGTH AT 80,000 FEET: INSULATION RESISTANCE: -70C TO + 125C 300,000 FEET 200 g FOR 6 mS 100 g FOR 6 mS 30 g 33-3000Hz 20 g 33-3000Hz 0.4 g2/Hz 50-2000Hz 0.2 g2/Hz 50-2000Hz 1250 V rms 1000 V rms
Z, Y, & X ENCLOSURES W & M ENCLOSURES (STUD MTG.) Z, Y, & X ENCLOSURES W & M ENCLOSURES (STUD MTG.) Z, Y, & X ENCLOSURES W & M ENCLOSURES (STUD MTG.) ALL CIRCUITS TO GROUND AND CIRCUIT TO CIRCUIT. COIL TO GROUND
350 V rms 100 M MINIMUM INITIAL (500 VDC) AFTER LIFE OR ENVIRONMENTAL TESTS 50 M MINIMUM OPERATE TIME AT NOMINAL VOLTAGE: DC RELAYS 10 ms OR LESS 15 ms OR LESS AC RELAYS RELEASE TIME AT NOMINAL VOLTAGE: DC RELAYS 10 ms OR LESS 50 ms OR LESS AC RELAYS
* Max. contact opening under vibration or shock 10 microseconds
9
SERIES
FCA-210
Tyco Electronics Mid-Range Military/Aerospace Relays
10 AMPERES, DPDT
Below are shown the standard terminal types and the enclosures available. Specify the assembly as indicated under How To Order. Dimensions are shown in inches .010 and (Millimeters .25).
TERMINALS
SOCKET PINS ARE GOLD PLATED POLARIZING PINS ARE TIN/LEAD PLATED CIRCUIT BOARD PINS ARE TIN/LEAD PLATED DIMENSIONS EXCEPT AS NOTED: INCHES .010 (MILLIMETERS .25)
CODE "D"
.270 (6.86) .330 .030 (8.83) (.76) +.006 .115 - (.010) (2.92) +(.152) - (.254)
Socket Pins 115 VAC
.050 .005 (1.27 (13) Silicone Rubber Gasket
ENCLOSURES
All Enclosures have Cupro-Nickel Cans bright acid tin/lead plated after assembly to terminal headers. Dimensions: Inches .010 (mm .25) "A" AC Coils 1.125 in. (28.57) Max. DC Coils 1.010 in. (25.65) Max. CODE "Z"
"A" MAX.
CODE "A" Socket Pins - All DC Coils
.270 (6.86) .300 (7.62) .062 +.002 Dia. - .001 +.05 (1.57 - .02) Polar Pin
.050 .005 (1.27 (.127) Silicone Rubber Gasket
.070 (1.78) .050 (1.27)
-X2
.062 (1.57) Dia.
+X1
.027 .003 (.69) (.08) .525 Max. (13.34)
-X2
BLUE BEAD
.062 .001Dia. Pin (1.57 .02)
1.025 Max. (26.04)
CODE "E"
BLUE BEAD .062 .001Dia. Pin (1.57 .02 ) 8 Plcs
Socket Pins 28 VAC Coils
Same as Code "D" Except polarizing Pin turned 90 to this plane.
POLARIZING PIN
CODE "Y" "A"
MAX. .040 (1.02)
CODE "B" Circuit Board Pins - All DC Coils
.270 (6.86) .300 (7.62) .062 +.002 Dia. - .001 (1.57 +.05) Polar - .02 Pin
CODE "F"
.270 (6.86) .330 .030 (8.83) (.76) +.006 .115 - (.010) (2.92) +(.152) - (.254)
Circuit Board Pins 115 VAC Coils
FULL R 4 PLCS
.156 (3.96)
1.025 Max. (26.04) 1.446 (36.73) 1.396 (35.46)
.150 (3.8) .375 (9.52)
.525 Max. (13.34) .070 (1.78) .050 (1.27) 1.718 Max. (43.64)
-X2
-X2
CODE "X"
.375 (9.52)
"A" MAX.
.150 (3.8) .550 (13.97) AC COILS 1.025 Max. (26.04) 1.396 (35.46) 1.446 (36.73) .500 (12.70) DC COILS
BLUE BEAD
.062 .001Dia. Pin (1.57 .02) 8 Plcs
.062 (1.57) Dia.
+X1
.027 .003 (.69) (.08)
BLUE BEAD
.062 +002 Dia. Pin -.001
FULL R 4 PLCS
CODE Solder Hook Terminals "C" HOOK TERMINALS TIN/LEAD PLATED
CODE "F"
Circuit Board Pins 28 VAC Coils
Same as Code "D" Except polarizing Pin turned 90 to this plane.
.525 Max. (13.34) 1.718 Max. (43.64) .312 CODE (7.92) "W" 6-32 UNC-2A 2 Studs * .040 (1.02)
POLARIZING PIN
.375 (9.52)
.300 .020 (7.62) .51
-X2
0.80 DIA (2.03) +.002 .062 - .001Dia. Term. (1.57 ) +.05 8 Plcs - .02
CODE "H"
All Pins Bright Acid Tin/lead .400 (10.61) .200 (5.08) .100 R TYP. .200 .200 (5.08) (5.08)
90 Solder Pins
"A" MAX.
.031 (.787)
1.025 Max. (26.04) .525 Max. (13.34) .625 (5.88)
.257 (6.52)
+X1
BLUE BEAD
.200 (5.08)
BLUE BEAD +.002 .062 - .001 Dia. 10
*Metric threads available,To specify use M in place of W
SERIES
FCA-210
Tyco Electronics Mid-Range Military/Aerospace Relays
10 AMPERES, DPDT
TERMINAL WIRING
DC COILS WITH TRANSIENT SUPPRESSION
POLARIZING PIN
DC COILS
AC COILS 115 VAC
POLARIZING PIN
AC COILS 28 VAC
POLARIZING PIN
POLARIZING PIN
1
X2
-
2
3 B
1
X2
-
2
3
1 B A
X2 AC X1
BLUE BEAD
2
3 B A
1
X2 AC X1
BLUE BEAD
2
3 B A
+
X1
BLUE BEAD
A +
+
X1
BLUE BEAD
+
NOTE: Polarity must be observed with DC coil supply. Relay is polarized with a permanent magnet and will not operate or be damaged by reverse polarity. Diodes used in transient suppression and in AC rectifier circuits have peak inverse voltage rating of 600 VDC minimum. Zener diodes have a minimum rating of 1 watt. Terminal designations are for reference only and do not appear on the header.
TERMINAL LAYOUT
.200 (5.08) .100 (2.54)
A1 -X2 A2 A3 B A
.100 (2.54)
.100 (2.54)
+X1
.200 (5.08)
.400 (10.16) .600 (15.24)
HOW TO ORDER
(EXAMPLE) RELAY TYPE TERMINALS (Socket Pins, DC Coil) ENCLOSURE (With Flanges) COIL (28 VDC With Transient Suppression). NOTE: Only DC coil models are QPL Approved
FCA-215FCA-210-A Y 4
11


▲Up To Search▲   

 
Price & Availability of FCA-215-AY4

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X